《船舶货泵舱起火.docx》由会员分享,可在线阅读,更多相关《船舶货泵舱起火.docx(2页珍藏版)》请在优知文库上搜索。
1、八、货泵舱起火Eight,pumpcabinfire发现者先大喊或击破就近报警点报警,后用通用报警报警,并用船用广播发布着火部门。Discoverershouldshoutanddestroythenearestalertpointtoalarm,iftherearemorethantwopeople,onlyonealarm,theotherstaytocontrolandputoutthefire.应到人员携带消防器材集合左后甲板Requiredpersonnelshouldcarryfirefightingequipmentmusterinleftsterndeck携带呼吸器、消防服:A
2、BMMManagefirehydrants,firehose,nozzle:BOSUND/CC/MM管理消防栓、水带、水枪:BOSUNBD/CManagementoffirehydrants,firehose,watergun:BOSUND/CC/MM管理操纵固定式二氧化碳灭火装置:3/04/EManagefixedcarbondioxidefire-extinguishingdevice:3/0携带手提灭火器:C/0BOSUND/CC/MME/C(ETC)Carryaportablefireextinguisher:C/0BOSUND/CC/MM(ETC)管理国际通岸接头:3/03/EMan
3、ageconnectionofinternationalshore:3/03/E管理操纵主、应急消防泵:C/E3/EManageoperatingmain,emergencyfirepump:C/E3/E切断有关电路,关闭风机:E/ECutoffallthecircuit,turnoffthefan:E/Eoffthecircuit,thefan:E/E隔离火场附近易燃物:BOSUND/CC/MMIsolateflammablenearthefire:BOSUND/CC/MM关闭防火门、窗,通道,通风口等:C/EBOSUND/CC/MMClosefiredoor,window,ventchan
4、nel,spiracle:C/EBOSUND/CC/MM做好放艇准备:BOSUN4/EStandbylaunchingboat:BOSUN3/E携带急救药箱:2/0Carryafirstaidkit:2/0携带担架,氧气复苏仪:C/CCarryastretcher,oxygenrecoveryinstrument:C/C清点人数报告人数,奔赴现场Nosecount.Reportthenumber,rushedtothescene全船人数20人,驾驶台:3人,机舱:3人,集合点:14人.Thewholeshipnumber20people,bridge:3,engineroom:3people,
5、musterpoint:14.救护队:3人,消防队:8人,支援队:3人Rescueteam:3,thefirefightingteam:8,3:supportteam查明火情,向驾驶台报告。Identificatethefire,reportconditiontothebridge.两名消防员进入用手提灭火机灭火(如为乙类火,小火用C02、干粉灭火机灭火)。Twofirefightersenterinwiththeportablefireextinguishingputtingoutthefire(useC02anddrypowderfireextinguisherifitisclassBfi
6、reorsmallfire).驾驶台做记录,向有关港口当局和公司汇报。Bridgerecordstotheportauthoritiesandcompany.报告:E/E报告切断有关电路,关闭风机Report:E/Ereportaboutcuttingoffcircuit,closingthefanBSN报告已隔离火场附近易燃物BOSUNreporttheflammablehasbeenisolatednearbythefireC/MM关闭防火门、窗,通道,通风口C/MMclosingfiredoor,window,channel,vent探火员发现有一名伤员,用吊索把人从泵间吊出,交给救护队
7、,实施人工呼吸等进行施救。Firedetectorfoundawounded,hangoutthewoundedfromthepumproombyasling,delivertorescueteam,implementationofartificialrespirationforrescue.消防员报告火势大无法扑灭,则撤离泵间。thefiremenreport:fireistoobigtoextinguishedthenevacuatethepumproom.用消防水冷却货泵间四周。usethefirefightwatercoolingpumproomaround.清点人数,待所有人员撤离后
8、,关门和关闭通风,准备启动HALOX灭火系统。Rollcallthenumber,afterallthestaffretreating,closethedoorandclosethevent,readytostarttheHALONfireextinguishingsystem.通知支援队启动大型HALON灭火系统。NotificationsupportteamtostartalargeHALONfireextinguishingsystem.火被扑灭后,泵间外壁温度明显下降,探火员进入探火,戴呼吸器,铝柏衣进入。AfterThefirewasextinguished,thetemperatu
9、reofpumproomouterwal1decreasedsignificantly,firedetectorenterintothefire,wearingbreathingequipment,aluminumplatinumclothing.探火员报告火已被完全扑灭Firedetectionreportthefirehasbeenextinguished.救护队报告,伤员已苏醒,轻度烧伤,需要送岸治疗。rescueteamreports,woundedwererevivedwithminorburns,needtosendthelandtreatment.向船长报告,清点人数。Reporttothecaptain,rollcallthenumber.讲评讲解灭火方案,提出好的意见和建议。Commentandappraisethequenchschemeandproposeadvice